DEE-23116 Introduction to Smart Grids - 14.12.2015

Exam text content

The text is generated with Optical Image Recognition from the original exam file and it can therefore contain erroneus or incomplete information. For example, mathematical symbols cannot be rendered correctly. The text is mainly used for generating search results.

Original exam
TRY DEE-23116 Introduction to Smart Grids P. Järventausta
Exam 14.12.2015 — Own calculator is NOT allowed to use in the exam

 

You can answer in English or in Finnish

L

Are the following statements true?

You have three options to be selected (Y=yes / N=no / DK = don't know). Right answer means

one point (+1p) and the wrong answer one minus point (-1p). If you choose the option DK (=

don't know), you will get zero point (Op).

a) A microgrid can be determined as a segment of Smart Grid with intended island
operation capability.

b) European Union's 20-20-20 targets means that 60 % of energy consumption in
EU comes from renewable resources.

c) One essential feature of Smart Grids is that the power flows are controllable and
multi-directional.

d) In Nordic electricity market there is only one common electricity exchange for
the wholesale market, but independent transmission system operators (TSOs) in
each countries.

f£) In meshed (i.e ring) configuration relay protection practices are simple and
power losses are higher than in radial configuration of power grid.

g)In the traditional concept of power balance management customers?
consumption has followed production, but in the concept of Smart Grids
production follows consumption (i.e. freguency is controlled only by generators)

. Define shortly the following terms or concepts (1.5 p/each)

a) Day-ahead (spot) market
b) Time-of-use pricing

b) HEMS

c) V2G

List
a) the main benefits which can be achieved by *Demand Response” (3p)

b) the drivers and barriers for electrification of road transportation (3p)

Describe briefly

a) Reasons why power electronics is increasingly widely applied in distribution
networks (3p)

b) The reclose seguence of MV feeder protection relay for temporary and
permanent faults (3p)


We use cookies

This website uses cookies, including third-party cookies, only for necessary purposes such as saving settings on the user's device, keeping track of user sessions and for providing the services included on the website. This website also collects other data, such as the IP address of the user and the type of web browser used. This information is collected to ensure the operation and security of the website. The collected information can also be used by third parties to enable the ordinary operation of the website.